Skip Navigation


BJA Advance Access originally published online on July 31, 2009
British Journal of Anaesthesia 2009 103(3):394-399; doi:10.1093/bja/aep198
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
103/3/394    most recent
aep198v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in BJA
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Zanner, R.
Right arrow Articles by Schneider, G.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zanner, R.
Right arrow Articles by Schneider, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Author [2009]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournal.org

Time delay of electroencephalogram index calculation: analysis of cerebral state, bispectral, and Narcotrend indices using perioperatively recorded electroencephalographic signals

R. Zanner, S. Pilge, E. F. Kochs, M. Kreuzer and G. Schneider*

Department of Anaesthesiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, D-81675 Munich, Germany

* Corresponding author. E-mail: g.schneider{at}lrz.tum.de

Background: Monitoring of anaesthetic depth with EEG-derived indices may detect EEG changes associated with awareness and thereby help to decrease the incidence of intraoperative awareness with postoperative recall. All currently available monitors need varying time periods to calculate a new index when reacting to changes in anaesthetic depth. The exact time delay for calculation of new index values is unknown. In a previous study, we used simulated EEG signals and found considerable time lags for the cerebral state index (Danmeter, Odense, Denmark), the bispectral index (Aspect Medical Systems Inc., Newton, MA, USA), and the Narcotrend index (MonitorTechnik, Bad Bramstedt, Germany). The aim of this study was to investigate whether the time delays observed with simulated EEG signals also applied to real EEG data.

Methods: We used perioperatively recorded EEG data from a database corresponding to the awake state, general anaesthesia, and suppression of cortical activity, respectively. After a switch from one state of consciousness to another, the time necessary for all indices to adjust the index value to the underlying input signal was measured.

Results: We found time delays for all indices between 24 (7) and 122 (23) s before the new state was indicated. In accordance with our previous results, these time delays were not constant and depended on the particular starting and target index value. Results were different for decreasing and increasing values.

Conclusions: Our results may show a limitation of the value of electronic EEG indices in prevention of awareness with recall. Furthermore, due to different time delays for ascending and descending values, the results of pharmacodynamic studies may be influenced by this phenomenon.

Keywords: equipment, monitors; monitoring, bispectral index; monitoring, depth of anaesthesia; monitoring, electroencephalography


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in BJA:

In the September 2009 BJA ...

BJA 2009 103: xii. [Extract] [Full Text]  





Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.