Skip Navigation


BJA Advance Access originally published online on April 2, 2008
British Journal of Anaesthesia 2008 100(5):631-636; doi:10.1093/bja/aen072
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
100/5/631    most recent
aen072v1
Right arrow E-Letters: Submit a response to the article
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by McCormick, A. S. M.
Right arrow Articles by Thomas, P. W.
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCormick, A. S. M.
Right arrow Articles by Thomas, P. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Board of Management and Trustees of the British Journal of Anaesthesia 2008. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Plasma concentrations and sedation scores after nebulized and intranasal midazolam in healthy volunteers

A. S. M. McCormick1,*, V. L. Thomas1, D. Berry2 and P. W. Thomas3,4

1 Shackleton Department of Anaesthetics, Southampton University Hospital NHS Trust, Tremona Road, Southampton SO16 6YD, UK
2 Medical Toxicology Unit, Avonley Road, London SE14 5ER, UK
3 Dorset Research and Development Support Unit, Poole Hospital NHS Trust, Longfleet Road, Poole, Dorset BH15 2JB, UK
4 Institute of Health and Community Studies, Bournemouth University, Bournemouth, UK

* Corresponding author: Department of Anaesthetics, Poole Hospital NHS Trust, Longfleet Road, Poole, Dorset BH15 2JB, UK. E-mail: law_mckenna{at}hotmail.com

Background: An efficacious, reliable, and non-invasive route of administration for midazolam, a drug used for sedation and pre-anaesthetic medication, would have obvious advantages. This study compares two potential methods of administering midazolam by the nasal and nebulized routes.

Methods: Midazolam (0.2 mg kg–1) was given by both nebulizer and nasally by liquid instillation to 10 healthy volunteers in a randomized, double-blind crossover study. Plasma concentrations of midazolam, Ramsay sedation scores, visual analogue scores, critical flicker fusion frequency, and parameters of cardiovascular and respiratory function were measured over 60 min and summarized using ‘area under the curve’.

Results: Nasal instillation caused more sedation than nebulized administration. This was demonstrated by higher Ramsay sedation scores (P=0.005), lower visual analogue scores (P<0.001), and lower critical flicker fusion frequency (P<0.02). Nasal instillation was associated with higher plasma concentrations of midazolam (P<0.001). Unpleasant symptoms were recorded by six volunteers in the intranasal and one in the nebulized group (P=0.06).

Conclusions: There was some evidence that midazolam caused less discomfort when given by nebulizer compared with intranasally. Comparative bioavailability of midazolam, estimated by the ratio (nebulized:nasal) of area under the 60 min plasma concentration curve, was 1:2.9. A higher dose may need to be administered for adequate pre-anaesthetic medication when midazolam is given by nebulizer.

Keywords: sedation; pharmacokinetics, midazolam; premedication, midazolam


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.